Below is a schematic of a vapor power plant in which water steadily circulates through the four components. The water flows through the boiler and condenser at constant pressure and through the turbine and pump adiabatically. Kinetic and potential energy effects can be ignored. Process data follow: Process 4-1: constant pressure at 8 MPa from saturated liquid to saturated vapor Process 2-3: constant pressure at 8 kPa from x2